{"product_id":"ce-contec-kt88-1016-16-channel-digital-eeg-and-brain-mapping-system-with-electroencephalogram-for-epilepsy-intracranial-inflammation-and-cerebrovascular-disease-diagnosis-in-clinical-and-hospital-settings","title":"CE CONTEC KT88-1016 16 Channel Digital EEG and Brain Mapping System with Electroencephalogram for Epilepsy, Intracranial Inflammation, and Cerebrovascular Disease Diagnosis in Clinical and Hospital Settings","description":"\u003ch1\u003eCONTEC KT88-1016 16 Channel Digital EEG and Brain Mapping System for Clinical Neurological Diagnosis\u003c\/h1\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/020bebf9-7fbf-4575-844c-e62672b9688a.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe CONTEC KT88-1016 represents a dedicated digital electroencephalogram (EEG) and brain electric activity mapping system engineered for clinical and hospital environments. Its primary function is to collect EEG signals via electrodes, process them through integrated amplification and analogue-to-digital transformation, and perform PC-based automatic analysis including Fast Fourier Transform (FFT) to generate colour-depth electroencephalogram displays. This system is applicable for checking and aiding in the diagnosis of several neurological conditions, notably epilepsy, intracranial inflammation, cerebrovascular diseases, and brain tumours. With 16 channels dedicated to EEG and an optional 2 channels for ECG, it supports comprehensive data acquisition. The device is built around practical clinical needs, offering up to 24 hours of continuous recording, a suite of analysis tools, and a focus on secure, reliable operation backed by professional safety isolation. Its compact aluminium housing, measuring 186 mm by 135 mm by 89.2 mm and weighing 550g, is designed for functional deployment in diagnostic settings.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications and Performance\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/36429d2a-5757-4e1c-af3b-8025717d5ddc.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe KT88-1016 is defined by a set of measurable performance parameters that establish its capability for accurate signal acquisition and processing in a medical context. These specifications provide the foundation for its diagnostic utility.\u003c\/p\u003e\n\u003ch3\u003eSignal Acquisition and Channel Configuration\u003c\/h3\u003e\n\u003cp\u003eThe core of the system is its 16-channel EEG input, supplemented by an optional 2-channel ECG module, providing a comprehensive view of electrical brain activity. It employs a bioelectricity amplifier specifically designed for distilling brainwave signals. The sampling rate is set at 100 dots per second with an accuracy of 12 bits, ensuring detailed temporal resolution of the captured waveforms. Input impedance is rated at ≥10MΩ, which helps minimise signal loading, while the system's common-mode rejection ratio (CMRR) is ≥90dB, effectively reducing interference. The magnification multiple is fixed at 10,000, and the noise level is maintained at ≤5µV peak-to-peak, contributing to clear signal definition suitable for clinical review.\u003c\/p\u003e\n\u003ch3\u003eDisplay, Playback, and Filtering Controls\u003c\/h3\u003e\n\u003cp\u003eFor clinician review, the system offers extensive control over how EEG data is presented. The display speed, analogous to paper speed, is adjustable across multiple settings: 5, 10, 15, 30, 60, and 120 mm\/s. Similarly, waveform amplitude can be set from 1 mm\/50µV up to 50 mm\/50µV across twelve discrete steps. During case playback, the speed can be increased from real-time (1x) up to 60 times faster for efficient review. A fully digital filter system allows filters to be enacted freely as required, and includes a 50Hz interference suppression feature rated at ≥30dB. These adjustable parameters allow medical personnel to tailor the visual analysis to their specific diagnostic focus and judgment.\u003c\/p\u003e\n\u003ch3\u003eSafety and Electrical Specifications\u003c\/h3\u003e\n\u003cp\u003ePatient and operator safety is addressed through several integrated design features. The device is classified as a Class II, type BF applied part, indicating a high degree of protection against electric shock. It incorporates a professional isolation transformer and a dual power supply isolation system, complemented by optoelectronic data transmission to ensure electrical safety. The patient leak current is kept below 10µA, adhering to stringent medical equipment standards. Power is supplied via a standard USB 5V DC interface, which also serves as the primary data transmission port, simplifying connectivity and reducing cable clutter.\u003c\/p\u003e\n\u003ch2\u003eSoftware Features and Analytical Functions\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/3a9f712b-85a3-4ec0-a795-62f175f69d39.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eBeyond hardware acquisition, the system's value is significantly enhanced by its software suite, which provides powerful tools for waveform analysis, case management, and reporting. These features are designed to streamline the diagnostic workflow for medical professionals.\u003c\/p\u003e\n\u003ch3\u003eWaveform Analysis and Marking Tools\u003c\/h3\u003e\n\u003cp\u003eThe software includes an electronic frequency ruler, enabling convenient measurement of basic information such as period, amplitude, and frequency from any appointed EEG waveform. A partial enlarging window allows for accurate, detailed inspection. Clinicians can mark EEG waves corresponding to events like opening eyes, closing eyes, or flashing stimuli with different, user-defined colours. These event markers ensure corresponding waveform segments can be rapidly located during case playback. Additionally, any section of the EEG wave can be clipped, stored, and selected for automatic analysis to distill various parameters, facilitating focused review on areas of interest.\u003c\/p\u003e\n\u003ch3\u003eAutomated Detection and Data Presentation\u003c\/h3\u003e\n\u003cp\u003eAutomated analysis functions perform power spectrum analysis and pathologic wave detection on appointed waveforms. The system can display multiple analysis graphs on the same screen, including various Brain Electrical Activity Mapping (BEAM) displays, numerical BEAM, compressed spectrum graphs, and trend graphs. This multi-graph presentation supports a holistic assessment of brain activity patterns. The case management function itself is robust, providing multiple means for research and quick statistical information, and includes convenient case export and import capabilities.\u003c\/p\u003e\n\u003ch3\u003eReporting, Data Exchange, and Optional Modules\u003c\/h3\u003e\n\u003cp\u003eReporting is streamlined through an integrative image and character report editor, with the capability to switch reports into Microsoft Word document format for easy integration into patient records. For academic collaboration and further analysis, case files can be transformed into standard EDF (European Data Format) and BDF (Biosemi Data Format). Optional functional expansions include a video module, where a USB camera provides isochronous sampled image recording alongside EEG waveforms, and an SpO2 (peripheral capillary oxygen saturation) monitoring function, allowing for more comprehensive patient monitoring during extended recordings.\u003c\/p\u003e\n\u003ch2\u003eOperational Use and System Configuration\u003c\/h2\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/5a16adea-d928-4471-9c42-53268fac3c63.webp\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe practical deployment of the KT88-1016 in a clinical setting is guided by its operational parameters, accessory set, and configuration flexibility. These elements ensure it can be adapted to different departmental needs and user preferences.\u003c\/p\u003e\n\u003ch3\u003eElectrode Placement and Stimulation\u003c\/h3\u003e\n\u003cp\u003eThe system adheres to the internationally recognised 10\/20 system for electrode placement, ensuring standardised positioning across subjects for comparable results. During operation, leads can be changed even while replaying recorded data, and different types of combined leads are supported during the initial sampling phase. For evoked potential studies, the package includes a multifunctional flash stimulator with a USB interface. This strobe light can be controlled either manually or automatically, and a specific flash stimulation scheme can be programmed and executed during the sampling process, aiding in the investigation of photic driving responses.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Specifications and Storage\u003c\/h3\u003e\n\u003cp\u003eThe device is designed to operate reliably within a defined environmental envelope. The operational temperature range is from +5°C to +40°C, at a relative humidity of ≤85%, and within an atmospheric pressure range of 700 hPa to 1060 hPa. For storage or transport when not in use, the acceptable range widens to -20°C to +55°C at ≤90% relative humidity, under the same pressure conditions. This ensures the system remains protected during non-operational periods in a hospital or clinic environment.\u003c\/p\u003e\n\u003ch3\u003eAccessories and Physical Setup\u003c\/h3\u003e\n\u003cp\u003eThe standard package provides all necessary components for basic operation. This includes the EEG leads and electrodes, a data line, patient headgear, the strobe light with its dedicated power supply, a user manual, an earth wire for grounding, an EEG bracket for electrode placement, and the main aluminium block unit. This comprehensive set allows for immediate setup and use following the provided guidelines. The system parameters and various display modes can be customised as required, allowing different users or institutions to configure the interface and analysis preferences to meet their specific clinical protocols and diagnostic workflows.\u003c\/p\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/604be8ea-68d7-47c3-8650-1f0130e04042.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/60c936f8-8de2-46fb-acc4-e62de2105bbd.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/6c5f4838-63bd-4652-a064-2b505dc8e5eb.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/9c485c9b-6ec5-4a88-8529-33e1f8e7239c.webp\"\u003e\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003cimg alt=\"CONTEC KT88-1016 16 channel digital EEG and brain mapping system in aluminium housing.\" src=\"https:\/\/images.seoo.uk\/src\/products\/shopify_export\/US10\/1220\/2025-10-02\/original-image\/cc2395b2-919b-4a98-b23f-ebc9ee096fa9.webp\"\u003e\u003c\/div\u003e","brand":"yvbajw-qj","offers":[{"title":"KT88","offer_id":56491183472966,"sku":"CJZN1707371-KT88","price":1266.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0996\/3228\/3974\/files\/6c5f4838-63bd-4652-a064-2b505dc8e5eb.webp?v=1777757036","url":"https:\/\/fiorevale.com\/products\/ce-contec-kt88-1016-16-channel-digital-eeg-and-brain-mapping-system-with-electroencephalogram-for-epilepsy-intracranial-inflammation-and-cerebrovascular-disease-diagnosis-in-clinical-and-hospital-settings","provider":"Fiorevale","version":"1.0","type":"link"}